500 LPH RO Plant

TECHNICAL SPECIFICATION RO 500 LITRES MS:

 

1Skid
 MOCSS
 No.1
 MakeAqua Plus
 Capacity  RO 500 liters.
 TypeRectangle
2Feed Pump
 TypeSelf Priming
 No.1
 MakeCRI/Crompton
 Capacity  1500 LPH
 Pressure  3 KG/ CM2
 Power Consumption1 HP
3Sand Filter
 TypeVertical
 Diameter14 Inch 
 Height65 Inch
 MOCFRP
 Type of OperationManual
 Back wash Time 10-15 minutes 
 Size of multi port valve1 ”
4Carbon  Filter 
 TypeVertical
 Diameter14 Inch 
 Height65 Inch
 MOCFRP
 Type of OperationManual
 Back wash Time 10-15 minutes 
 Size of multi port valve1”
5Micron Cartridge Filter 
 Flow rate1.5 M3/hr.
 MOCPP
 Length of Cartridge20” Jumbo
 Dia. Of cartridge4”
 No. of Cartridge2 Nos.
 Rating20 Micron + 5 Micron 
 Make Aqua Plus 
6Anti  Scaling dosing system
 Pump1 Set
 MakeAqua Italy / E-Dose / Hi-tech
 Quantity1
 TypeElectronic Diaphragm Type
 Capacity0 to 4 LHP
 Quantity of Tank1 Nos.
 Capacity of Tank100 Liters
 MOC of TankHDPE.
7Pressure Pump
 TypeVertical centrifugal multi stage
 No.1
 MakeCRI/ Crompton
 Power consumption 2 HP
 Flow 1.5 M3
 Pressure  15 Kg/CM2
8Pressure Tube
 Item                             RO module consisting of membrane Housing With RO membrane mounted on skid.
 MOCFRP
 Dia.4”
 Length40”
 Qty. 

2 Nos.

 

9Membrane
 Type                TFC POLYAMIDE  
 Size 4” dia. x 40” 
 Qty.2 Nos.
 MakeFlimtec, USA
 Rating0.0001 Micron.

 

 

 

 

 

INSTRUMENTATION:

ADigital Conductivity OR TDS Meter
 Quantity1 Nos.
 Maximum Temperature40 Degree Centigrade
 Location RO Permeate.
BFlow Indicators
 Quantity2 Nos.
 Type Float Type Panel Mounted.
 Maximum Op. Temp.40 Degree Centigrade.
 Measuring Points

1) RO Module Product Flow

2) Waste Water Flow 

CPressure Gauges
 Quantity2 Nos.
 Range0-20 Kg / Cm2.
 Location
  1. Raw Water Inlet.
  2. Pressure Tube Inlet.
DHigh Pressure Switch And Low Pressure Switch
 Quantity1+1 Nos.
 Location Before & After High Pressure Pump.
Pressure Control Valve
 Location Reject Water Line 
 Nos.1 Nos.
 Make Spring System USA.
FAuto Flushing switch with Solenoid Valve.
GElectronic Control Panel With A meter, Voltmeter, indicators, On off Switch 

 

 

PIPE LINE  

  1. CPVC pipe line from Feed Pump to Inlet of High Pressure Pump. 
  2. SS pipe line from outlet of High Pressure pump to final water end point of system.

SKID              

  1. MS box frame.