100 Liter Ro Plant

TECHNICAL SPECIFICATION RO 100 MS

 

1Skid
 MOCMS
 No.1
 MakeAqua Plus
 Capacity  RO 100 ltr.
 TypeRectangle
2Feed Pump
 TypeSelf Priming
 No.1
 MakeSpeed
 Capacity  100 LPH
 Pressure  3 KG/ CM2
 Power Consumption0.5 HP
3Sand Filter
 TypeVertical
 Diameter8 Inch 
 Height35 Inch
 MOCFRP
 Type of OperationManual
 Back wash Time 10-15 minutes 
 Size of multi port valve¾ ”
4Anti  Scaling dosing system
 Pump1 Set
 MakeAqua Italy / E-Dose / Hi-tech
 Quantity1
 TypeElectronic Diaphragm Type
 Capacity0 to 4 LHP
 Quantity of Tank1 Nos.
 Capacity of Tank20 Liters
 MOC of TankHDPE.
5Cartridge Filter Housing
 Flow rate         0.5 M3/hr.
 MOC   FRP  
 Length of Housing20” 
 Dia. Of Housing2.5”
 No. of Cartridge Housing3 Nos.
6Carbon Cartridge Filter
 Flow rate0.5 M3/hr.
 MOCCarbon
 Length of Cartridge20”
 Dia. Of cartridge2”
 No. of Cartridge1 Nos.
 Rating20 + 5 
 Make “Purtrex”, Osmonics, USA.
7Micron Cartridge Filter
 Flow rate0.5 M3/hr.
 MOCPP
 Length of Cartridge20”
 Dia. Of cartridge2”
 No. of Cartridge2 Nos.
 Rating20 Micron + 5 Micron 
 Make “Purtrex”, Osmonics, USA.
8Pressure Pump
 TypeVertical centrifugal multi stage
 No.1
 MakeSpeed
 Power consumption 0.5 HP to 1.5 HP
 Flow 0.5 M3
 Pressure  10 Kg/CM2
9Pressure Tube
 Item                             RO module consisting of membrane Housing With RO membrane mounted on skid.
 MOCFRP
 Dia.2.5”
 Length40”
 Qty. 

1 Nos.

 

10Membrane
 Type                TFC POLYAMIDE  
 Size 20*40
 Qty.1 Nos.
 MakeFilmtec, Desal® Osmonics , USA
 Rating0.0001 Micron.

INSTRUMENTATION:

ADigital Conductivity OR TDS Meter
 Quantity1 Nos.
 Maximum Temperature40 Degree Centigrade
 Location RO Permeate.
BFlow Indicators
 Quantity1 Nos.
 Type Float Type Panel Mounted.
 Maximum Op. Temp.40 Degree Centigrade.
 Measuring PointsRO Module Product Flow
CPressure Gauges
 Quantity2 Nos.
 Range0-20 Kg / Cm2.
 Location
  1. RO Module Inlet.
  2. RO Module Reject Flow.
DHigh Pressure Switch And Low Pressure Switch
 Quantity1+1 Nos.
 Location Before & After High Pressure Pump.
Pressure Control Valve
 Location Reject Water Line 
 Nos.1 Nos.
 Make Spring System USA.
FAuto Flushing switch with Solenoid Valve.
GElectronic Control Panel With A meter, Voltmeter, indicators, On off Switch 

 

PIPE LINE  

  1. CPVC pipe line from Feed Pump to Inlet of High Pressure Pump. 
  2. SS pipe line from outlet of High Pressure pump to final water end point of system.

 

 

 

SKID              

  1. MS box frame.